Latest CM3 runs (e.g. cm3-run-16-09-2024) have a net TOA energy flux around 2.7 W/m^2 initially.
Met Office GC5 AMIP runs were tuned to give the desired radiation balance at N216, not N96. The tuning is described at https://code.metoffice.gov.uk/trac/gmed/wiki/ticket/573/TicketDetails describes the radiation tuning of the N216 version.
This is an extract of the table near the end of https://code.metoffice.gov.uk/trac/gmed/wiki/ticket/577/TicketSensitivityTests
| rsut | rlut | net | |
|---|---|---|---|
| Obs CERES EBAF 4.1 | 99.0 | 240.3 | +1.0 |
| N96 RC3 | 98.56 | 239.53 | +2.31 |
| N216 RC3 | 99.07 | 240.59 | +0.74 |
RC3 is almost the same as the final version, except for an update to the boundary layer buoyancy https://code.metoffice.gov.uk/trac/jules/ticket/1242.
Alejandro Bodas's presentation at the 2023 Momentum Workshop says they retuned the GC5-N96ORCA1 PI control aiming at rsut=99, rlut=240.5, close to CERES EBAF4 values (because UKESM suggested PI and current were pretty close). Used two_d_fsd_factor = 1.70, cape_timescale =2700 s in place of standard two_d_fsd_factor=1.65 cape_timescale=1800.0, though not clear if this is the final value.