Skip to content

Evolution - bind/clone issue #11

@IdefixRC

Description

@IdefixRC

@fishpepper, I recompiled the latest master and tested binding and TXClone again.
Unfortunately I still have the same issue:

Bind mode: Put the RX into bind mode (2 solid LED's), as soon as I hit bind on the TX one RX led starts blinking as it should indicating that it receives the bind packets. However upon restart of both TX and RX, the RX simply blinks indicating no connection.

TX Clone: I tried that next. Put the Evolution in Clone TX mode, powered my taranis up and hit bind. The evolution started with the autocalibration etc and finished with "please switch off now".
After powering it back up the RX still could not connect (powering the taranis up makes it connect instantly to the taranis).

Any ideas on what I'm doing wrong? I assume that the TX module connections are fine given it can send and receive (at least looks like that from the tests above). Could there be a HW connection issue to the module which would not show up during bind but only in transmit operation?

Also you recommended to check the hoptable and place a while(1); after the debug print with the hop table for now. => can you point me at the right place for that? I checked the src but could not find the obvious place for the hoptable debug.