This repository contains a collection of my custom components for ESPHome.
Use latest ESPHome
with external components and add this to your .yaml definition:
external_components:
- source: github://SzczepanLeon/esphome-components@mainComponent to receive wMBus frame (via CC1101), create HA sensor and send decoded value. You can also use this component with wmbusmeters HA addon: https://github.com/SzczepanLeon/esphome-components/blob/main/docs/wmbus.md
NOTE: Configuration for version 3.x is described here
- don't know meter type (driver) and don't know ID
wmbus:
all_drivers: True
log_all: TrueThen in logs you will have trace with driver name and ID:
[17:13:07][I][wmbus:085]: apator162 [0x00148686] RSSI: -44dBm T: 4e4401068686140005077a350040852f2f0f005B599600000010aa55000041545a42850Bd800437d037301c5500000564B00009e46 (79) T1 A
- meter type (driver) and ID are known, but you don't know how to add sensors (map decoded data to sensor)
wmbus:
all_drivers: False
log_all: False
sensor:
- platform: wmbus
meter_id: 0x00148686
type: apator162
key: "00000000000000000000000000000000"
sensors:
- name: "my hot water RSSi"
field: "rssi"
accuracy_decimals: 0
unit_of_measurement: "dBm"
device_class: "signal_strength"
state_class: "measurement"
entity_category: "diagnostic"Then in logs you will have trace with telegram:
[17:13:07][I][wmbus:085]: apator162 [0x00148686] RSSI: -44dBm T: 4e4401068686140005077a350040852f2f0f005B599600000010aa55000041545a42850Bd800437d037301c5500000564B00009e46 (79) T1 A
You can decode that telegram on wmbusmeters and create sensors.
find interesting data (in that case total_m3), split it into field (total) and unit (m3) and create sensor in YAML. In YAML config please use units from HA (ie. "m³" not "m3", etc).
wmbus:
all_drivers: False
log_all: False
sensor:
- platform: wmbus
meter_id: 0x00148686
type: apator162
key: "00000000000000000000000000000000"
sensors:
- name: "my hot water RSSi"
field: "rssi"
accuracy_decimals: 0
unit_of_measurement: "dBm"
device_class: "signal_strength"
state_class: "measurement"
entity_category: "diagnostic"
- name: "my hot water"
field: "total"
accuracy_decimals: 3
unit_of_measurement: "m³"
device_class: "water"
state_class: "total_increasing"
icon: "mdi:water"time:
- platform: sntp
id: time_sntp
external_components:
- source: github://SzczepanLeon/esphome-components@main
refresh: 0d
components: [ wmbus ]
wmbus:
mosi_pin: GPIO13
miso_pin: GPIO5
clk_pin: GPIO2
cs_pin: GPIO14
gdo0_pin: GPIO15
gdo2_pin: GPIO16
led_pin: GPIO0
led_blink_time: "1s"
frequency: 868.950
all_drivers: False
sync_mode: True
log_all: True
mqtt:
broker: 10.0.0.88
username: mqttUser
password: mqttPass
clients:
- name: "wmbusmeters"
ip_address: "10.0.0.22"
port: 7227
sensor:
# add driver to compile list (will be available for autodetect), don't create sensor
- platform: wmbus
type: itron
# add sensor with defined type (driver will be also added to compile list)
- platform: wmbus
meter_id: 0x12345678
type: apator162
key: "00000000000000000000000000000000"
sensors:
- name: "my hot water RSSi"
field: "rssi"
accuracy_decimals: 0
unit_of_measurement: "dBm"
device_class: "signal_strength"
state_class: "measurement"
entity_category: "diagnostic"
- name: "my hot water"
field: "total"
accuracy_decimals: 3
unit_of_measurement: "m³"
device_class: "water"
state_class: "total_increasing"
icon: "mdi:water"
# add more sensors, one without field (name will be used)
- platform: wmbus
meter_id: 0xABCD4321
type: amiplus
sensors:
- name: "my current power consumption in Watts"
field: "current_power_consumption"
accuracy_decimals: 1
unit_of_measurement: "w"
device_class: "power"
state_class: "measurement"
icon: "mdi:transmission-tower-import"
- name: "total energy on T1"
field: "total_energy_consumption_tariff_1"
accuracy_decimals: 3
unit_of_measurement: "kwh"
device_class: "energy"
state_class: "total_increasing"
icon: "mdi:transmission-tower-import"
- name: "voltage_at_phase_1"
accuracy_decimals: 0
unit_of_measurement: "v"
device_class: "voltage"
state_class: "measurement"
icon: "mdi:sine-wave"
# sensor with offset, type should be autodetected
- platform: wmbus
meter_id: 0x11223344
sensors:
- name: "cold water from Apator NA-1"
field: "total"
accuracy_decimals: 3
unit_of_measurement: "m³"
device_class: "water"
state_class: "total_increasing"
icon: "mdi:water"
filters:
- offset: 123.0
# if mqtt defined, JSON with all decoded fields will be published to broker
- platform: wmbus
meter_id: 0x22113366
type: vario411
text_sensor:
- platform: wmbus
meter_id: 0xABCD1122
type: izar
sensors:
- name: "Izar current_alarms"
field: "current_alarms"In wmbus platform:
- mosi_pin (Optional): CC1101 MOSI pin connection. Defaults to
GPIO13. - miso_pin (Optional): CC1101 MISO pin connection. Defaults to
GPIO12. - clk_pin (Optional): CC1101 CLK pin connection. Defaults to
GPIO14. - cs_pin (Optional): CC1101 CS pin connection. Defaults to
GPIO2. - gdo0_pin (Optional): CC1101 GDO0 pin connection. Defaults to
GPIO5. - gdo2_pin (Optional): CC1101 GDO2 pin connection. Defaults to
GPIO4. - led_pin (Optional): Pin where LED is connected. It will blink on each telegram. You can use all options from Pin Schema.
- led_blink_time (Optional): How long LED will stay ON. Defaults to
300 ms. - frequency (Optional): Rx frequency in MHz. Defaults to
868.950 MHz. - sync_mode (Optional): Receive telegram in one loop. Defaults to
False. - log_all (Optional): Show all received telegrams in log. Defaults to
False. - all_drivers (Optional): Compile with all drivers. Defaults to
False. - clients (Optional):
- name (Required): The name for this client.
- ip_address (Required): IP address.
- port (Required): Port number.
- format (Optional): Telegram format to send. HEX or RTLWMBUS. Defaults to
RTLWMBUS. - transport (Optional): TCP or UDP. Defaults to
TCP.
- mqtt (Optional):
- broker (Required): Broker IP address.
- username (Required): User name.
- password (Required): password.
- port (Optional): Port number. Defaults to
1883. - retain (Optional): If the published message should have a retain flag on or not. Defaults to
False.
- mqtt_raw (Optional): Send raw telegrams over mqtt, even for non configured sensors. Defaults to
False. - mqtt_raw_parsed (Optional): Wheteher raw frames should be send after parsing header. If so, their address will be included in topic, and json data. If
True, then address will be appended to topic:(...)/raw/<address>. Otherwise(...)/raw. Defaults toTrue. - mqtt_raw_prefix (Optional): Topic prefix for raw frames:
<mqtt_raw_prefix>(/)<app_name>/wmbus/raw[/<address>]. Defaults to"" - mqtt_raw_format (Optional): Format of raw frames to send.
RTLWMBUSorJSON. Defaults toJSON.
NOTE: MQTT can be defined in wmbus component or in ESPHome level. The later will reuse connection managed by ESPHome, while former whill open and close connection on each packet. Bbroker defined on wmbus component level will take priority (event if both are defined).
sensor:
- meter_id (Optional, int): Meter ID. Can be specified as decimal or hex.
- type (Optional, string): Meter type. When not defined, driver will be detected from telegram.
- key (Optional): Key for meter, used in payload decoding process. Defaults to
"". - sensors (Optional):
- id (Optional, string): Manually specify the ID for code generation. At least one of id and name must be specified.
- name (Optional, string): The name for the sensor. At least one of id and name must be specified.
- field (Optional): Field from decoded telegram (without unit). If field is not present then name is used.
- unit_of_measurement (Required): Unit for field defined above.
- All other options from Sensor.
text_sensor:
- meter_id (Optional, int): Meter ID. Can be specified as decimal or hex.
- type (Optional, string): Meter type. When not defined, driver will be detected from telegram.
- key (Optional): Key for meter, used in payload decoding process. Defaults to
"". - sensors (Optional):
- id (Optional, string): Manually specify the ID for code generation. At least one of id and name must be specified.
- name (Optional, string): The name for the sensor. At least one of id and name must be specified.
- field (Optional): Text field from decoded telegram. If field is not present then name is used.
- All other options from Text Sensor.
Supported drivers: almost all from wmbusmeters version 1.17.1 (without drivers from file)
Szczepan, GPL, 2022-2024