Description

Optionally set the target temperature for the heated bed, then wait in a loop until that target temperature is reached.

Examples

 M190      ; Wait for the heated bed to reach target temperature
 M190 S190 ; Set the heated bed temperature and wait

Arguments

 S<celsius> Optional. The temperature to set and wait for. Don't wait if cooling down.
 R<celsius> Optional. The temperature to set and wait for. Always wait.

Discussion

M190 changes the target temperature for the heated bed and waits for the temperature to be reached before proceeding with the next command. If you don't want to pause for heating, use M109.

Notes

  • If both S and R parameters are given, S takes precedence.

Clone this wiki locally